1. Teldor- CAT-7 網路線
    Teldor-CAT -6A電腦網路線
    Teldor-CAT -6電腦網路線
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Teldor-CAT -6A電腦網路線

    Teldor-9827682xxx Cat. 6 2x[4x2x23/1 AWG] Fig-8 F/FTP FR-LSZHS  8對耐燃低煙無鹵雙併鋁箔隔離網路線
    看原圖
    Teldor-9827682xxx

    商品編號: Teldor-9827682xxx

    Teldor-9827682xxx Cat. 6 2x[4x2x23/1 AWG] Fig-8 F/FTP FR-LSZHS 8對耐燃低煙無鹵雙併FTP網路線
     
       
     

    Cat. 6 2x[4x2x23/1 AWG] Fig-8 F/FTP FR-LSZH

    Part Number:
    9827682xxx
     

    Applications: Trunk Cable for Local Area Networks, Indoor use, fixed installations, High bandwidth digital applications with low BER, High data rates
    General Construction: The cable contains two groups of 4 individually aluminum foil-shielded twisted pairs, each cabled together with a drain wire, and an overall foil shield. The two groups are laid in parallel in a FIG-8 ("Siamese") formation and jacketed with a FR-LSZH compound. The cable exceeds  IEC 61156-5 Cat. 6 and Cat. 5e requirements.
     
    Outer Jacket Material: FR-LSZH
    Weight: 111 kg/km
    Design & Materials
    Conductor Material: Bare Copper
    Conductor Size: 23 AWG
    Conductor Construction: Solid
    Insulation Material: PO
    Insulation O.D.: 1.31 mm nom.
    Conductor unit identification: Solid/stripe
    Color code: Per TIA/EIA 568-B
    Ind. Shield Material: Aluminum/Polyester Foil
    Ind. Shield Design: 100% Coverage
    Overall Shield Design: 100% Coverage
    Overall Shield Material: Aluminum/Polyester Foil
    Overall Foil Shield: Yes
    Overall Drain-wire Material: Tinned Copper
    Overall Drain-wire size: 0.41 mm
    Overall Drain-wire Construction: Solid
    Total number of wires: 16
    Outer Jacket Dimension - X: 15.8 mm nom.
    Outer Jacket Dimension - Y: 7.5 mm nom.
    Outer Jacket Color: See TELDOR Jacket Code
    Marking: Teldor Standard, Per request
    Standards
    Standards: IEC 61156, ISO/IEC 11801, RoHS 2002/95/EC
    Flamability Rating: IEC 60332-1, UL 1581 VW-1
    Performance
    Electrical Properties:  
    Cat. 6 Screened-Pair Horizontal Cables*
     
    Freq.
    MHz
    Attenuation
    dB/100m
    20oC
    PS NEXT Loss
    dB
    NEXT Loss
    dB
    RL
    dB
    PS ELFEXT
    dB
    ELFEXT
    dB
    Typical
    Value
    Cat. 6
    Typical
    Value
    Cat. 6
     
    Typical
    Value
    Cat. 6
    Typical
    Value
    Cat. 6
    Typical
    Value
    Cat. 6
    Typical
    Value
    Cat. 6
    1 2.0 2.8 90.0 72.3 93.0 75.3 22.0 20.0 90.0 65.0 93.0 68.0
    4 3.7 3.8 85.0 63.3 88.0 66.3 25.0 23.0 90.0 53.0 93.0 56.0
    10 5.7 6.0 85.0 57.3 88.0 60.4 28.0 25.0 80.0 45.0 83.0 48.0
    20 8.1 8.5 85.0 52.8 88.0 55.8 28.0 25.0 80.0 39.0 83.0 42.0
    30 10.0 10.5 85.0 50.1 88.0 53.1 27.0 23.8 70.0 35.5 73.0 38.5
    100 19.0 19.9 80.0 42.3 83.0 45.3 24.0 21.1 63.0 25.0 66.0 28.0
    150 23.6 24.9 80.0 39.7 83.0 42.7 22.0 18.8 60.0 21.5 63.0 24.5
    200 27.7 29.1 80.0 37.8 83.0 40.8 21.0 18.0 58.0 19.0 61.0 22.0
    250 31.4 33.0 77.0 36.3 80.0 39.3 20.0 17.3 55.0 17.0 58.0 20.0
    300 34.8 N/A 77.0 N/A 80.0 N/A 19.0 17.3 52.0 N/A 55.0 N/A
    400 41.0 N/A 72.0 N/A 75.0 N/A 19.0 17.3 49.0 N/A 52.0 N/A
    500 46.7 N/A 72.0 N/A 75.0 N/A 19.0 17.3 47.0 N/A 50.0 N/A

    *Supplied cables meet the minimum Cat. 6 transmission requirements as per IEC 61156-5 Ed. 2
     
    Frequency Range: 1 - 250 MHz
    Impedance: 100 Ω
    Coupling Attenuation: Type II
    Max. DC Resistance : 73 Ω/km@20°C
    Max. Resistance Unbalance: 2 %
    Capacitance Unbalance: 1.2 pF/m max.
    Velocity of Propagation: 75 % nom.
    Propagation Delay Skew: 30 ns/100m max.
    Dielectric Strength: 700 V/minute
    Dielectric Strength to Shield: 700 V/minute
    Min. Insulation Resistance : 5 GΩ•km
    Max. Tensile Strength - Short Term: 150 N
    Min. Bend Radius: 70 (small axis) mm
    Max. Operating Temperature: +60 °C
    Min. Operating Temperature: -40 °C

     

     
     
       

     
     
     
    About the Teldor P/N Jacket Color Code

     
    At Teldor, we try and offer our customers the greatest flexibility in product choice. The cable's outer jacket color is no exception. That is why most Teldor P/Ns in this website have a non-color specific or generic suffix: "xxx" (or "C" for FiberOptic cables). Using the color code chart provided below, you can specify the Teldor P/N in your order or RFQ with the desired jacket color! For example, replace the "xxx" with 103 for a red jacket, or the "C" in a FiberOptic P/N with "R".
     
    COLOR
    Copper Cable Code ("xxx")
    FiberOptic Cable Code ("C")
    Black
    101
    B
    White
    102
    W
    Red
    103
    R
    Blue
    104
    U
    Yellow
    105
    Y
    Green
    106
    E
    Orange
    107
    O
    Purple
    108
    P
    Grey
    109
    G
    Light Grey
    129
    L
    Ivory
    177
    I
    Brown
    201
    N
    Pink
    202
    K