    Teldor-9926A24xxx Cat. 6A 4x2x23/1 AWG S/FTP ND FR-LSZH IEC60332-3 耐燃低煙無鹵鋁箔銅網隔離網路線
    看原圖
    Teldor-9926A24xxx

    商品編號: Teldor-9926A24xxx

    Teldor-9926A24xxx Cat. 6A 4x2x23/1 AWG S/FTP ND FR-LSZH IEC60332-3 
    耐燃低煙無鹵鋁箔銅網隔離網路線

    Cat. 6A 4x2x23/1 AWG S/FTP ND FR-LSZH IEC60332-3

    Part Number:
    9926A24xxx
     

    Applications: Indoor use, fixed installations, High bandwidth digital applications with low BER, High data rates
    General Construction:
    The cable contains 4 individually aluminum-foil screened twisted pairs(aluminum face upwards), an overall tinned copper braid to a S/FTP form and jacketed with FR-LSZH compound.
     
    Cable transmission performance exceed the requirements of IEC 61156-5  Cat. 6A (500 MHz), Cat. 6 (250 MHz) and Cat. 5e.
    Outer Jacket Material: FR-LSZH
    Outer Diameter: 8.2 mm nom.
    Weight: 71 kg/km
    Design & Materials
    Conductor Material: Bare Copper
    Conductor Size: 23 AWG
    Conductor Construction: Solid
    Insulation Material: SFS PO
    Insulation O.D.: 1.35 mm nom.
    Conductor unit identification: Solid/stripe
    Color code: Per TIA/EIA 568-B
    Ind. Shield Material: Aluminum/Polyester Foil
    Ind. Shield Design: Aluminum face outwards
    Conductor unit lay-up: Pairs
    Overall Shield Design: Braid
    Overall Shield Material: Tinned-copper braid
    Overall Braid Shield: Yes
    Overall Braid Material: Tinned Copper
    Braid Coverage: 40 % nom.
    Total number of wires: 8
    Outer Jacket Color: See TELDOR Jacket Code
    Marking: Teldor Standard, Per request
    Standards
    Standards: IEC 61156, ISO/IEC 11801, RoHS 2002/95/EC
    Flamability Rating: IEC 60332-1, IEC 60332-3 , UL 1581 VW-1
    Performance
    Electrical Properties:  
    Cat. 6A Screened-pair Horizontal Cables*
     
    Freq.
    MHz
    Attenuation
    dB/100m
    20oC
    PS NEXT Loss
    dB
    NEXT Loss
    dB
    RL
    dB
    PS ANEXT
    dB
    PS ELFEXT
    dB
    ELFEXT
    dB
    Typical Value
    Cat. 6A
    Typical
    Value
    Cat. 6A
    Typical Value
    Cat. 6A
    Typical Value
    Cat. 6A
    Typical Value
    Cat. 6A
    Typical Value
    Cat. 6A
    Typical Value
    Cat. 6A
    1 2.0 2.0 95.0 72.3 98.0 75.3 22.0 20.0 70.0 67.0 85.0 65.0 88.0 68.0
    4 3.7 3.8 95.0 63.3 98.0 66.3 25.0 23.0 70.0 67.0 73.0 53.0 76.0 56.0
    10 5.6 5.9 95.0 57.3 98.0 60.3 28.0 25.0 70.0 67.0 65.0 45.0 68.0 48.0
    20 7.9 8.4 90.0 52.8 93.0 55.8 28.0 25.0 70.0 67.0 59.0 39.0 62.0 42.0
    30 9.7 10.3 85.0 50.1 88.0 53.1 27.0 23.8 70.0 67.0 55.4 35.4 58.4 38.4
    100 18.0 19.1 80.0 42.3 83.0 45.3 24.0 21.1 67.0 62.5 45.0 25.0 48.0 28.0
    150 22.4 23.6 78.0 39.7 81.0 42.7 22.0 18.8 66.0 59.8 41.5 21.5 44.5 24.5
    200 26.0 27.6 78.0 37.8 81.0 40.8 21.0 18.0 65.0 58.0 49.0 19.0 52.0 22.0
    250 29.4 31.0 75.0 36.3 78.0 39.3 20.0 17.3 63.0 56.5 37.0 17.0 40.0 20.0
    300 32.5 34.3 75.0 35.1 78.0 38.1 19.0 17.3 62.0 55.3 35.5 15.5 38.5 18.5
    400 38.0 40.0 70.0 33.3 73.0 36.3 19.0 17.3 61.0 53.4 33.0 13.0 36.0 16.0
    500 43.0 45.2 70.0 31.8 73.0 34.8 19.0 17.3 59.0 52.0 31.0 11.0 34.0 14.0
    600 47.6 N/A 70.0 N/A 73.0 N/A 19.0 N/A 57.0 N/A 30.0 N/A 33.0 N/A
    700 52.0 N/A 70.0 N/A 73.0 N/A 19.0 N/A 55.0 N/A 29.0 N/A 32.0 N/A






















    *Supplied cables meet the minimum Cat. 6A transmission requirements as per IEC 61156-5 Ed. 2
     
    Frequency Range: 1 - 500 MHz
    Impedance: 100 Ω
    Coupling Attenuation: Type I
    Max. DC Resistance : 73 Ω/km@20°C
    Max. Resistance Unbalance: 2 %
    Capacitance: 44 pF/m
    Capacitance Unbalance: 1.2 pF/m max.
    Velocity of Propagation: 78 % nom.
    Propagation Delay Skew: 25 ns/100m max.
    Dielectric Strength: 700 V/minute
    Dielectric Strength to Shield: 700 V/minute
    Min. Insulation Resistance : 5 GΩ•km
    Max. Tensile Strength - Short Term: 120 N
    Min. Bend Radius: 50 mm
    Max. Operating Temperature: +60 °C
    Min. Operating Temperature: -40 °C
     
    About the Teldor P/N Jacket Color Code

     
    At Teldor, we try and offer our customers the greatest flexibility in product choice. The cable's outer jacket color is no exception. That is why most Teldor P/Ns in this website have a non-color specific or generic suffix: "xxx" (or "C" for FiberOptic cables). Using the color code chart provided below, you can specify the Teldor P/N in your order or RFQ with the desired jacket color! For example, replace the "xxx" with 103 for a red jacket, or the "C" in a FiberOptic P/N with "R".
     
    COLOR
    Copper Cable Code ("xxx")
    FiberOptic Cable Code ("C")
    Black
    101
    B
    White
    102
    W
    Red
    103
    R
    Blue
    104
    U
    Yellow
    105
    Y
    Green
    106
    E
    Orange
    107
    O
    Purple
    108
    P
    Grey
    109
    G
    Light Grey
    129
    L
    Ivory
    177
    I
    Brown
    201
    N
    Pink
    202
    K